  RMA Shipping Procedures 
Packaging ASR 5500 Cards  ▀   
 
ASR 5500 Installation Guide  ▄  
 
   
195 
Rear Cards 
The packing instructions in this section apply to the following cards: 
 
Management Input/Output (MIO) or Management Input/Output Universal (UMIO) card 
 
Data Processing Card (DPC) or Data Processing Universal (UDPC) 
 
Data Processing Card v2 (DPC2) or Data Processing Universal v2 (UDPC2)  
Important:
  Rear cards use the larger ESD bags and shipping cartons. There are very slight differences in the 
cutouts at the rear of the MIO/UMIO, DPC/DPC2 or UDPC/UDPC2 foam. 
 
Important:
  MIO/UMIO cards must be returned with all SFP+ transceivers installed. Replacement MIO/UMIO 
cards are shipped with new SFP+ transceivers installed.  
The packaging sequence is as follows: 
Step 1 
Place the card inside the ESD bag; fold over and seal the bag with an ESD Label as shown in the figure below. 
 
Step 2 
Place the card in the carton as shown in the figure below.  
Step 3 
Place the top piece of foam over the card. 
Step 4 
Close the carton and seal it with shipping tape. See 
  
Step 5 
Place the shipping label on the outside of the carton. See