Cisco Cisco Packet Data Gateway (PDG) トラブルシューティングガイド

ページ / 580
Gx Interface Support   
▀  Rel. 7 Gx Interface 
 
▄  Cisco ASR 5000 Series Enhanced Feature Configuration Guide 
OL-22983-01   
The PCEF selects a PCC rule for each packet received by evaluating received packets against SDF filters of PCC rules 
in the order of precedence of the PCC rules. When a packet matches a SDF filter, the packet matching process for that 
packet is completed, and the PCC rule for that filter is applied. 
There are two types of PCC rules: 
 
 
Dynamic PCC Rules: Rules dynamically provisioned by the PCRF to the PCEF via the Gx interface. These PCC 
rules may be either predefined or dynamically generated in the PCRF. Dynamic PCC rules can be activated, 
modified, and deactivated at any time. 
 
Predefined PCC Rule: Rules preconfigured in the PCEF by the operators. Predefined PCC rules can be activated 
or deactivated by the PCRF at any time. Predefined PCC rules within the PCEF may be grouped allowing the 
PCRF to dynamically activate a set of PCC rules over the Gx reference point. 
Important:
  A third kind of rule, the static PCC rule can be preconfigured in the chassis by the operators. Static 
PCC rules are not explicitly known in the PCRF, and are not under control of the PCRF. Static PCC rules are bound to 
general purpose bearer with no Gx control. 
A PCC rule consists of: 
 
 
Rule Name: The rule name is used to reference a PCC rule in the communication between the PCEF and PCRF. 
 
Service Identifier: The service identifier is used to identify the service or the service component the SDF relates 
to. 
 
Service Data Flow Filter(s): The service flow filter(s) is used to select the traffic for which the rule applies. 
 
Precedence: For different PCC rules with overlapping SDF filter, the precedence of the rule determines which of 
these rules is applicable. When a dynamic PCC rule and a predefined PCC rule have the same priority, the 
dynamic PCC rule takes precedence. 
 
Gate Status: The gate status indicates whether the SDF, detected by the SDF filter(s), may pass (gate is open) or 
will be discarded (gate is closed) in uplink and/or in downlink direction. 
 
QoS Parameters: The QoS information includes the QoS class identifier (authorized QoS class for the SDF), the 
Allocation and Retention Priority (ARP), and authorized bitrates for uplink and downlink. 
 
Charging Key (i.e. rating group) 
 
Other charging parameters: The charging parameters define whether online and offline charging interfaces are 
used, what is to be metered in offline charging, on what level the PCEF will report the usage related to the rule, 
etc. 
Important:
  In this release, configuring the Metering Method and Reporting Level for dynamic PCC rules is not 
supported. 
PCC rules also include Application Function (AF) record information for enabling charging correlation between the 
application and bearer layer if the AF has provided this information via the Rx interface. For IMS, this includes the IMS 
Charging Identifier (ICID) and flow identifiers.