• secondary secondary-url secondary_url: Specifies the secondary location to which the system pushes
the EDR files when the primary location is unreachable or fails.
secondary_url must be the secondary location, and must be an alphanumeric string of 1 through 1024
characters in the "//user:password@host:[port]/directory" format.
• via local-context: Configuration to select LC/SPIO for transfer of EDRs. The system pushes the EDR
files via SPIO in the local context.
use-harddisk
The use-harddisk keyword is available only on the ASR 5000 and ASR 5500 chassis.
Important
ASR 5000: Specifies that on the ASR 5000 chassis the hard disk on the SMC be used to store EDR/UDR
files. On configuring to use the hard disk for EDR/UDR storage, EDR/UDR files are transferred from packet
processing cards to the hard disk on the SMC. Default: Disabled
ASR 5500: Specifies that on the ASR 5500 chassis the hard disk the FSC hard disk array be used to store
EDR/UDR files. On configuring to use the hard disk for EDR/UDR storage, EDR/UDR files are transferred
from DPCs to the hard disk array. Default: Disabled
+
Indicates that multiple keywords can be specified in a single command entry. When the "+" appears in the
syntax, any of the keywords that appear prior to the "+" can be entered in any order.
Usage Guidelines
Use this command to configure how the EDRs are moved and stored.
On the ST16 chassis, run this command only from the context where the EDR/UDR module is configured.
Running this command in any other context will fail and deliver an error message.
On the ASR 5000 or ASR 5500 chassis, you must run this command only from the local context. If you run
this command in any other context it will fail and result in an error message.
If PUSH transfer mode is configured, the L-ESS (for ASR 5000) or external server (for ASR 5500) URL to
which the EDR files need to be transferred to must be specified. The configuration allows a primary and a
secondary server to be configured. Configuring the secondary server is optional. Whenever a file transfer to
the primary server fails for four consecutive times, the files will be transferred to the secondary server. The
transfer will switch back to the original primary server when:
• Four consecutive transfer failures to the secondary server occur.
• After switching from the primary server, 30 minutes elapses.
When changing the transfer-mode from pull to push, disable the PULL from the L-ESS (for ASR 5000) or
external server (for ASR 5500) and then change the transfer mode to push. Make sure that the push server
URL configured is accessible from the local context. Also, make sure that the base directory that is mentioned
contains udr directory created within it.
When changing the transfer mode from push to pull, after changing, enable PULL on the L-ESS (for ASR
5000) or external server (for ASR 5500). Any of the ongoing PUSH activity will continue till all the scheduled
file transfers are completed. If there is no PUSH activity going on at the time of this configuration change,
all the PUSH related configuration is nullified immediately.
Command Line Interface Reference, Modes E - F, StarOS Release 19    
49
EDR Module Configuration Mode Commands
cdr