Cisco Cisco Tunnel Terminating Gateway (TTG) プリント
Global Configuration Mode Commands (T-threshold phspc)
threshold aaa-acct-failure ▀
Cisco ASR 5x00 Command Line Interface Reference ▄
5293
threshold aaa-acct-failure
Configures accounting failure, alarm or alert thresholds for the system.
Product
PDSN
GGSN
HA
ASN-GW
Privilege
Security Administrator, Administrator
Mode
Exec > Global Configuration
configure
Entering the above command sequence results in the following prompt:
[local]host_name(config)#
Syntax
threshold aaa-acct-failure high_thresh [ clear low_thresh ]
default threshold aaa-acct-failure
high_thresh
Default: 0
Specifies the high threshold number of accounting failures that must be met or exceeded within the polling
interval to generate an alert or alarm.
Specifies the high threshold number of accounting failures that must be met or exceeded within the polling
interval to generate an alert or alarm.
high_thresh
is an integer from 0 through 10000000. A value of 0
disables the threshold.
clear low_thresh
Default: 0
Specifies the low threshold number of accounting failures that maintains a previously generated alarm
condition. If the number of failures falls beneath the low threshold within the polling interval, a clear alarm
will be generated.
Specifies the low threshold number of accounting failures that maintains a previously generated alarm
condition. If the number of failures falls beneath the low threshold within the polling interval, a clear alarm
will be generated.
low_thresh
is an integer from 0 through 10000000. A value of 0 disables the threshold.
Important:
This value is ignored for the Alert model. In addition, if this value is not configured for the Alarm
model, the system assumes it is identical to the high threshold.
Usage
Accounting failure thresholds generate alerts or alarms based on the number of failed AAA accounting
message requests that occur during the specified polling interval. Accounting requests are counted for all
AAA accounting servers that the system is configured to communicate with.
Alerts or alarms are triggered for accounting failures based on the following rules:
message requests that occur during the specified polling interval. Accounting requests are counted for all
AAA accounting servers that the system is configured to communicate with.
Alerts or alarms are triggered for accounting failures based on the following rules:
Enter condition: Actual number of failures is greater than or equal to the high threshold.