Question
Answer
Related Cisco Support Community Discussions
Question
How to determine the current failure rate for an alarm at any time after the initial trigger. The initial
failure rate may be more obvious to find, but would one find the current fail rate possibly hours
later?
Answer
While the initial SNMP trap, log and the alarm track the intial failure rate of a monitored threshold,
it may not be obvious how to get the current fail rate. At the bottom of "show threshold", the
command reports the status of all alarms with regards to current fail rate in the last polling interval.
[local]PDSN> show threshold
Friday June 12 04:39:32 UTC 2015
Outstanding alarms:
        Threshold Name:    aaa-acct-failure-rate
        Alarm Source:      System
        Last Measured:     77%
        Raise Time:        2015-Jun-11+22:15:05
[local]PDSN> show thresh
Friday June 12 05:34:04 UTC 2015
Outstanding alarms:
        Threshold Name:    aaa-acct-failure-rate
Alarm Source: System Last Measured: 65%
        Raise Time:        2015-Jun-11+22:15:05
[local]PDSN> show thresh
Friday June 12 06:06:07 UTC 2015
Outstanding alarms:
        Threshold Name:    aaa-acct-failure-rate
        Alarm Source:      System
Last Measured: 61%
        Raise Time:        2015-Jun-11+22:15:05
[local]PDSN> show alarm outstanding verbose
Friday June 12 04:41:28 UTC 2015
Severity Object          Timestamp                          Alarm ID
-------- ----------      ---------------------------------- ---------------------
  Alarm Details
--------------------------------------------------------------------------------
Minor    Chassis         Thursday 
June 11 22:15:05
 U        5770524519230406656