Cisco Cisco Aironet 1200 Access Point
14
Open Caveats
OL-3159-01
Caveats
•
CSCdz15388—Repeater uses primary SSID to associate to infrastructure VLAN. If the primary
infrastructure security settings do not match, infrastructure stations may not be able to associate.
infrastructure security settings do not match, infrastructure stations may not be able to associate.
Workaround: Use the primary SSID for infrastructure stations.
•
CSCdy20169—When a 1200 series access point boots, it sometimes displays this warning:
(Warning) Routine "pktRouterRcvRtn" is unable to Take the forwardTbl Guard semaphore
You can ignore this message.
•
CSCdz26717—Setting a VLAN WEP key after already having set up encryption may leave the
VLAN in an invalid state.
VLAN in an invalid state.
Workaround: After setting a VLAN WEP key, disable and then enable the VLAN Enable setting.
•
CSCdy27831—When you set the default Unicast Address Filter to disallowed, you must reboot the
access point before the setting takes effect.
access point before the setting takes effect.
•
CSCdy29556—Symbol IP phone continuously associates and authenticates to an access point
configured with multiple VLANs
configured with multiple VLANs
When a Symbol IP phone is associated to a VoiP VLAN (Symbol extensions enabled), the phone
associates to the access point and is authenticated approximately every 2 seconds. The Symbol
phone shows a “No Network” error every 1 to 2 minutes.
associates to the access point and is authenticated approximately every 2 seconds. The Symbol
phone shows a “No Network” error every 1 to 2 minutes.
It also appears that Symbol phones do not work well when using a non-primary SSID. It is possible
that the phone does not perform an active Probe and therefore does not hear information about the
SSID it associated with in the beacon, causing it to reassociate and re authenticate.
that the phone does not perform an active Probe and therefore does not hear information about the
SSID it associated with in the beacon, causing it to reassociate and re authenticate.
There is no workaround for this caveat
.
•
CSCdy40031—Workgroup bridge does not function correctly when Classify Workgroup Bridge
as Network Infrastructure setting is set to No.
as Network Infrastructure setting is set to No.
Workaround: Always keep this setting set to Yes.
•
CSCdy59894—WEP client sometimes does not receive an IP address from DHCP.
Workaround—Browse to the Setup>Security>Radio Data Encryption (WEP) page and set the
Use of Data Encryption field to Full Encryption.
Use of Data Encryption field to Full Encryption.
•
CSCdy70443—A dual-mode access point in hot standby accepts associations from 5-GHz clients.
The clients will not receive a DHCP address and are effectively stranded, and will not pass data to
the wired backbone.
The clients will not receive a DHCP address and are effectively stranded, and will not pass data to
the wired backbone.
There is no workaround for this problem.