Cisco Cisco Prime Network Registrar 8.0 トラブルシューティングガイド

ページ / 24
 
 
 
 
 
 
 
 
 
 
 
 
Disaster Recovery Guide for Cisco Prime Network Registrar IPAM 8.0 
   11 
 
 
 
 
 
 
 
 
 
 
 
3.1.1.3  Updated copies of default.incontrol and incstatus 
 
As indicated previously, you must keep current copies 
of the default.incontrol and incstatus files from the 
Production Executive on the DR Executive.  Both files 
are located in $INCHOME/etc.  When copied to the 
DR Executive, they must be named 
default.incontrol.primary and incstatus.primary, 
respectively. 
 
3.1.2  Disaster Recovery Procedure 
This section describes the procedure necessary to initiate a DR 
event or exercise under this scenario. 
3.1.2.1  Change the IP of the DR Executive 
3.1.2.1.1 Linux/Solaris 
Change the IP address and associated parameters, including 
netmask and gateway, for the network interface using the 
accepted method of defining IP addressing information on that 
platform.  For example, on Red Hat this can be done using 
system-config-network
.  The IP address must be set 
to the IP address of the failed Production Executive, which 
must be offline. 
 
 
3.1.2.1.2 Linux/Solaris 
In order to “promote” the DR Executive so that it may 
become the Production Cisco Prime Network Registrar IPAM 
Executive, you must run the PromoteExec.sh script provided 
in the $INCHOME/etc/support directory of the Cisco Prime 
Network Registrar IPAM installation: 
> $INCHOME/etc/support/PromoteExec.sh