Cisco Cisco Prime Optical 9.6 開発者ガイド

ページ / 818
Cisco Prime Optical 9.6.3 GateWay/CORBA Programmer Reference Guide 
OL-28047-01
 
 
178
 
Name 
Type 
Input/ 
Output 
Description 
which to retrieve 
contained equipment and 
equipment holders. 
how_many 
unsigned long 
In 
Maximum number of 
EquipmentOrHolder_Ts 
to return in the first 
batch. 
nameList 
globaldefs::NamingAttributesList_T 
Out 
First batch of names. 
nameIt 
globaldefs::NamingAttributesIterator_I  Out 
Iterator to retrieve the 
remaining names. 
Throws 
globaldefs::ProcessingFailureException 
EXCPT_INTERNAL_ERROR - Raised in case of nonspecific EMS internal failure. 
EXCPT_INVALID_INPUT - Raised when meOrHolderName does not reference a managed 
element or an equipment holder. 
EXCPT_ENTITY_NOT_FOUND - Raised when managedElementOrEquipmentName references 
an object that does not exist. 
EXCPT_NE_COMM_LOSS - Raised when communication to the managed element is lost. 
EXCPT_TOO_MANY_OPEN_ITERATORS - Raised when the maximum number of iterators 
reaches 128. 
Compliance 
TMF-defined. 
3.6.3  getAllSupportedPTPs 
Synopsis 
void getAllSupportedPTPs( 
in globaldefs::NamingAttributes_T equipmentName, in unsigned long how_many, 
out terminationPoint::TerminationPointList_T tpList, out 
terminationPoint::TerminationPointIterator_I tpIt) 
raises(globaldefs::ProcessingFailureException); 
Description 
This interface enables an NMS to request the PTPs that are directly supported by specific 
equipment. The PTPs that are returned are those that share their physical layer with the 
primary equipment (that is, they represent a port on the equipment or are connected by a 
fiber, wire, and so on). 
If the equipment is protection equipment in a 1_FOR_N protection group, Prime Optical reports 
only the