The following diagram shows the position and the usage of the Signal Director and 
the Directional Coupler. 
 
A black dot is printed on the Signal Director and the Directional Coupler. The 
position of this black dot determines the number of the active ports in the GainStar 
Mini Node (See the enlarged part in the diagram above). If the black dot is at the 
top-right corner, only the RF output Main is the active port. If the black dot is at the 
bottom-left corner, both the RF output Main and RF output Aux are the active ports. 
When installing the Signal Director and the Directional Coupler, the number of the 
active RF output ports is decided by the user according to the specific application 
requirement.