Operations Alert Bulletin 
Recommended BFS QAM Frequency 
Rate for Multi-Stream CableCARD 
Code Download 
Background 
Multi-Stream CableCARD™ (M-Card™) modules running a software release 
prior to OS 1.5.2 (all versions of 1.5.2 software) will not recognize a Code Version 
Table (CVT) message from a BFS QAM whose output frequency is below 204 
MHz. The CVT message must be recognized for a download to occur. 
 
 
Recommendation 
Sites that have M-Card modules running a software release prior to OS 1.5.2 and 
have BFS QAMs with an output frequency below 204 MHz, must change the 
output frequency to a value above 204 MHz in order to successfully download 
M-Card software. Once the M-Card module is running a version of OS 1.5.2 or 
later software, it will recognize a CVT at any operational output frequency. 
To prepare for a M-Card software update, operators should do the following. 
 
Determine the BFS QAM output frequency. If it is below the threshold, read 
on. If not, this Operations Alert Bulletin does not apply to you. 
 
Determine if all of your M-Card modules are running a version of OS 1.5.2 or 
later software. If they are, this Operations Alert Bulletin does not apply to you. 
 
Contact Cisco
®
 Services to obtain the latest release of M-Card software and to 
schedule their assistance in downloading software to your M-Card modules.  
 
During a maintenance window, complete the tasks on the following pages to 
change the output frequencies, and restore them, if necessary, after the 
download. 
Note: Follow the instructions provided by Cisco Services to download 