Cisco Cisco D9804 Multiple Transport Receiver インストールガイド

ページ / 220
 
Chapter 5    Setup and Monitoring 
 
 
 
124 
78-4042990-01 Rev B 
 
Setting up Alarms 
Proceed as follows to configure the alarm settings: 
1  From the user interface of the D9804 MTR, click the System tab and then Alarms 
Setup icon from the sub-page. 
 
2  Set the Reset Delay, in seconds. It is the time delay for alarms to be cleared after 
the condition has been cleared. The range is from 1 to 60 seconds. The default is 5 
seconds. 
3  Click Apply
4  The alarms table displays a list of the alarm/fault messages. For each of the 
alarm message, you can set the Enable, Relay, and Trap information.  
Select Yes for Enable to report the alarm message. Select No, the fault won’t be 
reported and the alarm relays will not be triggered or change state. 
Note: Enable must be set to Yes for the Relay and Trap settings to be functional. 
5  Select Yes for Relay for the rear panel alarm relay to trigger to enable external 
equipment connected to the alarm port. Otherwise, select No. 
6  Set the Trap to Yes, and the SNMP trap message will be sent to the trap 
destination. Select No and the fault message will be ignored. 
7  Click Apply