Chapter 1    Introduction 
 
 
 
 
Disaster Recovery 
In the event  of a transmission  failure on the primary feed, the disaster recovery 
allows for continued  programming,  with limited to no downtime.  The failure 
condition  could be triggered  by one of the following  events: 
 
RF Lock Loss 
 
Unstable RF signal 
 
Transport Loss (RF locked, but no transport stream packets and NULL packets 
received) 
There  are two types of disaster recovery  implementations:  Local or Uplink. Local 
uses the disaster recovery  settings configured  on the D9854/D9854 -I receiver. Uplink 
uses the disaster recovery  profile  settings configured  on the PowerVu  Network 
Center  (PNC). This is optional and PNC Software Version  12.5 is required. 
Local Settings 
The local disaster recovery  settings are used if the PNC uplink is set to allow local 
disaster recovery  and the disaster recovery  profile on the unit is set to local. Once the 
receiver  detects a failure after the configured  signal loss timeout, it will initiate a 
disaster recovery  search  based on the search  path determined  by the disaster 
recovery  configuration.  A DR symbol is displayed on the front panel, and t he 
D9854/D9854-I web GUI displays a D/R in progress status. During a disaster, the 
receiver  will  attempt to tune to a different  backup transport, based on the search 
path configured.  The origin  transport consists of origin  transport tuning parameters 
and PE service  IDs, configured  in the Input menus. For more information  on the 
Input parameters, see RF1, RF2, RF3, RF4 (RFx) Input  (on page  77) for the front 
panel, and Setting up the RF Input  (on page 165) for the web GUI. 
Note: If you perform  a master PE channel  change  during a disaster recovery  search, 
the search will end, the current  tuning parameters will  be locked,  and the current 
channel  will  become  the origin  channel.  If you perform a tuning change  during  a 
disaster recovery  search, the search will  end, the current  user tuning parameters will 
become  the origin  tuning parameters, and the origin  may be updated by any of the 
NIT updates that follow. 
For example, the disaster recovery  is configured  as follows: 
Program 
Entry 
Origin  Transport 
Channel  Number 
Backup  1 
Transport 
Channel 
Number 
Backup  2 
Transport 
Channel 
Number 
Backup  3 
Transport 
Channel 
Number 
PE1 
101 
11 
101 
801 
PE2 
12 
1005