Chapter 2    Installing the Tap 
 
 
 
42 
4013399 Rev C 
To Attach the Twisted Pair Cable 
Follow these steps to attach the Twisted Pair cable. 
1  Open the PDU access cover by loosening the 3/8-inch screws. 
2  Carefully split the parallel wire to separate the twisted pair sheath from the coax 
sheath. 
 
CAUTION: 
A twisted pair power installation requires that the cable be prepared to 
properly mate with the twisted pair connectors.
 
 
You must use a utility knife or similar tool to cut the web close to the twisted 
pair sheath without nicking the outer cover of the twisted pair or the coax. 
 
Cut back the web a distance of 16 in. to 18 in. (40.6 cm to 45.7 cm), or 
whatever is appropriate for your installation, so that the coax can gently bend 
to connect to the drop F-ports and the twisted pair can enter at the bottom of 
the PDU. 
 
Ensure that the twisted pair sheath is prepared so that the outside of the 
sheath is circular as shown in the following diagram (with any burred edges 
removed). 
 
3  Cut off approximately 2 inches (5.1cm) of the outer sheath so that the two 
twisted pair wires are exposed. 
Note: The Twisted Pair PDU uses IDC connectors and does not require 
insulation to be removed. 
 
4  Lift the desired connector into the open position. 
  
WARNING: 
If installing the Twisted Pair PDU with PTCs installed (part numbers 750595 
and 750596), avoid electrical shock. AC power is present on the IDCs during 
installation.