MegaRAID SAS Controller Replacement Procedure 
OL-27138-01 
 
 
 
All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
 
12 
 
3.  Power off the server, disconnect the power cords from the power supplies, remove the 
power supplies and disconnect all the cables on the rear panel. 
4.  Place the chassis on a workstation and remove the top cover; 
5.  Note: Make sure you have an ESD strap on and you are properly grounded before 
doing the following steps: 
6.  Unscrew the bracket of card at slots 3. Disconnect the SATA cables attached to the 
card which connect to the internally mounted drives. 
7.  Pull out card mentioned above. 
8.  The new MegaRAID controller comes with the following two parts (see Figure 10) 
a.  The card itself (LSI MegaRAID 9261-8i) 
b.  The BBU for the card 
9.  Before installing the new MegaRAID controller, make sure that the BBU is installed 
onto the card properly. Figure 10 (below) shows the new MegaRAID card with the BBU 
installed. If the BBU is not installed onto the card, but instead provided in the box, 
follow the instructions in Appendix B to install it. 
 
 
Figure 10: New MegaRAID controller 
 
10.  Install the new MegaRAID controller card into slot 3 
– ensuring it is fully seated into the 
PCIe slot. 
11.  Re-attach slot screw to firmly attach new SAS controller into slot 3 and check that all 
slots screws are tightened. 
12.  Replace the top cover and put the chassis back. 
13.  Replace the power supplies and reconnect all cables, make sure you verify labels after 
all cables and fiber/copper are connected to interfaces.    
4.  Importing the Logical Drive Configuration 
After replacing the MegaRAID controller physically, the existing logical drive configuration on 
this server is no longer on the new MegaRAID controller but it still exists on the physical 
internal drives. So, we need to import the configuration from the internal drive to the new