Model 9811 / 9814 Controllers & Model 9801 / 9802 RIMs 
 
Specifications 
 
Connector 
Type 
SMC Loop 
Two RJ-14 telephone connectors (loop through) 
Video Backup 
BNC style connector 75
Ω, 1 V p-p, DC - 8 MHz 
Subcarrier Backup 
BNC style connector; 4.5 MHz audio subcarrier 
75
Ω, 1 V p-p, 4 MHz - 8 MHz 
IF Backup (future feature) 
 
F style connector 
Reference Input 
F style connector 
Reference Output 
F style connector 
R+, R- 
Terminal block, 2 terminals 600
Ω, 0 dBm, 20 Hz - 20 kHz 
GND 
Terminal block, 3 terminals 
L/MONO +, L/MONO - 
Terminal block, 2 terminals 600
Ω, 0 dBm, 20 Hz - 20 kHz 
SAP+, SAP- 
Terminal block, 2 terminals 600
Ω, 0 dBm, 20 Hz - 20 kHz 
ALM (normally closed), ALM (normally open), COMMON 
Terminal block, 3 terminals 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Ordering Information 
 
Description 
Part Number 
Model 9801 AC & DC Controller Rear Interface Module 
546020 
Model 9802 DC & DC Controller Rear Interface Module 
546280 
Note: A controller rear interface module must be present in the chassis for the controller module to be operational. 
 
 
 
 
 
 
 
 
 
 
 