Cisco Headend Digital Broadband Delivery System
Decide Binding Type
736107 Rev D
33
16 Click Yes to confirm that you want to stop the CCardServer process. The
indicator next to CCardServer turns red to identify that the process is stopped.
17 With the CCardServer process selected, click Process > Start Process. The
indicator next to CCardServer turns yellow and then green to identify that the
process has started.
Manual Binding
Manual binding is the process of manually adding the CableCARD module ID and
host ID to the DNCS through the CableCARD interface on the DNCS so that the
CableCARD module can receive "high-value" copy-protected services (services with
copy protection settings of either record once or record never).
Manually Binding a CableCARD Module and Host
1 On the DNCS Administrative Console, select the DNCS tab and then select one
1 On the DNCS Administrative Console, select the DNCS tab and then select one
of the following tabs based on the system release you have installed:
For SR 2.5/3.5/4.0 and earlier, select the Element Provisioning tab.
For SR 2.7/3.7/4.2 and later, select the Home Element Provisioning tab.
2 Click CableCARD. One of the following opens based on the System Release
your system uses:
For SR 2.7/3.7/4.2 and earlier, the CableCARD Data Summary screen opens.
For SR 2.7.1/3.7.1/4.2.1, the CableCARD Filter screen opens.
3 Click New CableCARD. The Add CableCARD screen opens.
Example: The following illustration is an example of an Add CableCARD screen
from SR 4.2.1. Screens in previous System Releases might look different.
4 Use the CableCARD diagnostic screens to locate the CableCARD ID, MAC
Address, and Host ID, or you can record the IDs that display on the host screen
after you insert the CableCARD module into a host.
5 Enter the CableCARD ID or the CableCARD MAC Address, and then enter the
Host ID in the appropriate fields.