RF Amplifier Module 
OL-29643-02 
35 
 
amplifier modules cover has been removed. 
 
Reverse Band Amplification Path Description 
The RF amplifier module provides all reverse signal amplification outside the optical 
transmitter modules in the GS7000 Node. It contains four independent reverse paths 
comprised of an AC bypass circuit, a bi-directional 20 dB down reverse test point, a 
diplex filter, an input pad, a low pass filter, a 6 dB switched attenuator, a 16 dB gain 
block, a second low pass filter, an RF on/off switch, a frequency response trim 
circuit, and a reverse configuration module. The 6 dB switched attenuator and RF 
on/off switch circuits allow each reverse path to have 6 dB (wink) and on/off 
capabilities. These circuits are controllable from the headend via the status monitor 
or locally via the local control module and a hand held controller. A serial 
communication link is provided between status monitor or local control module and 
the reverse band launch amplifier. Circuitry on the amplifier converts the serial 
communications to parallel control signals and routes them as needed. 
The RF amplifier module also provides the routing for the auxiliary ports, 5 to 210 
MHz reverse band local injection signals. Each of the two auxiliary port reverse band 
local injection paths is comprised of an AC bypass circuit, a bi-directional 20 dB 
down reverse test point, an input pad, and a reverse auxiliary 
jumper/amplifier/termination module. Signals from port 3 or port 6 of the nodes 
auxiliary path are directed by the reverse auxiliary/jumper/amplifier/termination 
module to the reverse configuration module. 
Reverse Configuration Module 
The reverse configuration module determines the reverse path topology in the RF 
amplifier module and GS7000 Node. The input signals from four independent 
amplifier module output ports and possibly the auxiliary reverse injection amplifier 
module port enter the reverse configuration module where they are combined 
and/or directed to one to four optical transmitters. Reverse path segmentation and 
or redundancy as well the ability to locally inject signals into the reverse path of the 
amplifier is set by plugging the appropriate reverse configuration module into the 
RF amplifier module. The reverse configuration module is a plug-in, field accessible 
module. See Reverse Configuration Module (on page 41) for more information. 
Reverse Auxiliary Jumper/Amplifier/Termination Module 
The reverse auxiliary jumper/amplifier/termination module determines how 
reverse band signals, locally injected into the RF amplifier modules auxiliary ports, 
are routed within the amplifier module. The reverse auxiliary jumper module directs 
signals for one of the RF amplifiers auxiliary ports to the reverse configuration 
module. 
The reverse auxiliary amplifier module amplifies signals for one or both of the RF 
amplifiers auxiliary ports and directs them to the reverse configuration module. The 
reverse auxiliary termination module terminates both auxiliary port reverse injection 
signal paths in 75 ohms as well as the path to the reverse configuration module.