Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split インストールガイド
Chapter 1 Overview
6
4024769 Rev A
Status Monitor/Local Control Module Description
Overview
A local control module and a status monitor are available for the Model GS7000
Node. A status monitor consists of a local control module with a transponder core
module installed in the housing. The same housing is used for both units.
Node. A status monitor consists of a local control module with a transponder core
module installed in the housing. The same housing is used for both units.
The units perform the following functions:
Local Control Module - controls redundancy and forward segmentation
Status Monitor - adds status monitoring capability to the local control module
Note: An existing local control module can be field upgraded to a status monitor
through the addition of a transponder core module. Refer to Model GS7000
GainMaker Node 1x/2x-3x-4x Local Control Module to Status Monitor Upgrade
Instructions, part number 4024770, for complete instructions.
through the addition of a transponder core module. Refer to Model GS7000
GainMaker Node 1x/2x-3x-4x Local Control Module to Status Monitor Upgrade
Instructions, part number 4024770, for complete instructions.
Local Control Module Description
The local control module locally monitors the following node voltages and signals:
Receiver optical input level (all receivers)
Transmitter optical output level (all transmitters)
AC power presence (for split AC powering cases, AC power from both sides
of node housing is monitored)
of node housing is monitored)
DC voltages from both primary and redundant power supplies
The local control module communicates serially with the RF amplifier module to
control the optional forward band redundancy switches on the forward
configuration module. It is a low-cost module that plugs into the status monitor
connectors on the optical interface board.
control the optional forward band redundancy switches on the forward
configuration module. It is a low-cost module that plugs into the status monitor
connectors on the optical interface board.
The local control module is equipped with a craft port to allow local control of the
optional forward band redundancy switches, the reverse band 6 dB (wink)
attenuators, and the reverse band on/off switches through a handheld controller.
All parameters monitored by the local control module can be reviewed using the
handheld controller.
optional forward band redundancy switches, the reverse band 6 dB (wink)
attenuators, and the reverse band on/off switches through a handheld controller.
All parameters monitored by the local control module can be reviewed using the
handheld controller.