Low or Degraded Reverse RF Signal 
4011881 Rev B 
87 
 
Possible cause 
Solution 
Reverse RF signal still low or 
degraded. 
ƒ 
Verify that any unused RF ports are properly 
terminated. 
ƒ 
Use a spectrum analyzer to look at the reverse 
RF input signal spectral quality at each reverse 
input test point and compare it to the reverse 
RF output signal spectral quality. 
Note: If degradation is generated by the 
downstream amplifier reverse RF signal, 
troubleshoot the RF amplifier feeding this 
station. 
ƒ 
Replace the amplifier module.