The trend recording configuration tab allows you to configure the interval for taking
each sample, and the IP address of the TFTP server to store the log files. The
interface also includes the option to enable/disable the log upload, the most recent
log upload record and the Refresh button to refresh the upload record.
1. Input the desired time interval for taking sample charts after Sample Interval. 1
minute per sample in the above case.
Note: Time interval is automatically converted into hours or days. For example,
Note: Time interval is automatically converted into hours or days. For example,
the input of 70 minutes will be converted to 1 hour and 10 minutes
automatically. The max sample interval is 2880 minutes (2 days).
2. Click on the drop-down box after Sample Enabled to enable/disable taking
samples for the trend track.
3. Verify the IP address of the TFTP server displayed after Log Server IP. Refer to
the Configuration Data section on page 3-18 to update the IP address if
necessary.
4. Verify the default filename after Log Filename Prefix or input a new file name
for the log.
Note: Use different file names to avoid overwriting the previous log records.
Note: Use different file names to avoid overwriting the previous log records.
5. Verify the default interval of each log in time points (every sample interval time)
or input a desired value after Log Interval. 10 minutes per log in the above case.
Note: The max number of time points is 1000.
Note: The max number of time points is 1000.
6. Click on the drop-down box after Log Upload Enabled to enable/ disable the
trend log upload.
Note: You can also click Upload All to upload all logs to the server, or click
Note: You can also click Upload All to upload all logs to the server, or click
Clear Trend Data to remove all the trend logs stored.
7. Click Apply to apply the configuration.
34
OL-32436-01