Cisco Model 6109 6 MHz Off-Air Reference (NTSC) インストールガイド

ページ / 500
 
Chapter 2    Hardware Installation 
 
 
 
28 
78-4021139-01 Rev D 
 
Rack Requirements 
The USRM can be installed in most industry standard four-post racks. The rack 
mounting rails are intended to be installed in a rack that meets the specifications of 
American National Standards Institute (ANSI)/Electronic Industries Association 
(EIA) standard ANSI/EIA-310-D-92, International Electrotechnical Commission 
(IEC) 297, and Deutsche Industrie Norm (DIN) 41494. 
Recommended Tools and Supplies 
You may need the following item to install the system in a four-post rack cabinet: 
 
#2 Phillips screwdriver 
The following section provides information about mounting the USRM using the 
provided angle support brackets. 
 
Installing the USRM in the Rack 
Follow these steps to install the USRM in the rack using the angle support brackets. 
 
  
CAUTION: 
Avoid personal injury and damage to this product! Be sure to support the 
product from underneath until it is securely positioned in the rack. Failure to 
do so could result in the product falling to the floor. The product could be 
damaged and you could be injured as a result. 
1  Make sure that the site requirements are met as outlined in Before You Begin in 
this chapter. 
2  Determine the approximate position in the equipment rack where you want the 
bottom of the USRM to be located and position the angle support brackets in the 
rack with the cut-outs in the brackets facing toward the back of the rack as 
shown in the following illustration.