Cisco Cisco 1 GHz GainMaker Amplifier データシート

ページ / 9
 
 
Data Sheet 
                                                                       Page 8 of 9 
Signal Directors 
Signal directors are used in the High Gain Dual and Low Gain Dual system amplifiers only. One 
signal director is required per amplifier to route and/or split forward RF signal to the Auxiliary output 
port(s). The signal director is available in splitter, DC-8, or DC-12 configurations for splitting the 
Auxiliary path signal to feed both Auxiliary ports, or as a jumper for routing all signals to a selected 
port.  
Table 12. 
Signal Directors 
– 1002 MHz (blue cover) 
Type 
 
Part 
Number 
Tap/   
Thru 
Leg 
Typical Insertion Loss (dB) at Various Frequencies (MHz) 
52 
70 
86 
550 
600 
650 
750 
870 
1002 
Jumper 
4008208 
Aux 2 
0.1 
0.1 
0.1 
0.2 
0.2 
0.2 
0.2 
0.2 
0.3 
Aux 1 
0.1 
0.1 
0.1 
0.4 
0.4 
0.5 
0.5 
0.6 
0.7 
2-way 
splitter 
4008364 
3.4 
3.4 
3.4 
3.8 
3.9 
3.0 
4.0 
4.1 
4.2 
DC-8 
 
4008365 
Thru 
1.7 
1.8 
1.8 
2.1 
2.1 
2.1 
2.1 
2.2 
2.3 
Tap 
8.3 
8.3 
8.3 
8.2 
8.3 
8.2 
8.1 
8.0 
8.0 
DC-12 
4008366 
Thru 
1.1 
1.1 
1.1 
1.2 
1.2 
1.3 
1.3 
1.4 
1.5 
Tap 
12.4 
12.4 
12.4 
11.8 
11.8 
11.7 
11.7 
11.7 
11.8 
Table 13. 
 Signal Directors 
– 870 MHz (blue cover) 
Type 
 
Part 
Number 
Tap/   
Thru 
Leg 
Typical Insertion Loss (dB) at Various Frequencies (MHz) 
52 
70 
86 
550 
600 
650 
750 
870 
Jumper 
589281 
0.1 
0.1 
0.1 
0.2 
0.2 
0.2 
0.3 
0.3 
2-way 
splitter 
589357 
3.7 
3.7 
3.7 
3.7 
3.7 
3.7 
3.8 
4.0 
DC-8 
 
589363 
Thru 
1.7 
1.7 
1.7 
1.8 
1.9 
1.9 
1.9 
2.0 
Tap 
8.3 
8.3 
8.3 
8.3 
8.2 
8.2 
8.1 
8.1 
DC-12 
589367 
Thru 
1.0 
1.0 
1.0 
1.2 
1.2 
1.3 
1.4 
1.6 
Tap 
12.1 
12.1 
12.1 
11.7 
11.6 
11.6 
11.6 
11.6 
Note: The GainMaker plug-in signal director produces loss in the forward signal path only.  The signal director 
is physically located inboard of the forward/reverse diplex filters in the forward path of the amplifier.  Therefore, 
there are no reverse path losses associated.  Auxiliary port reverse input pad values must be selected 
accordingly during system design when using the splitter, DC-8, or DC-12 signal director in a station. 
System Trim 
A plug-in system trim may be used to counter the frequency response effects of some passive 
devices in the coaxial plant. A mid frequency, single dip trim (Model MSD-1NGF) is available for all 
870 MHz GainMaker amplifiers. The System Trim part number is 714446. 
Table 14. 
 Fuse Kits /Surge Protectors 
System Amplifier 
Part Number 
Slow Blow Fuse Kit, 4 amp (contains 4 fuses) 
735628 
Slow Blow Fuse Kit, 8 amp (contains 4 fuses) 
735630 
Slow Blow Fuse Kit, 15 amp (contains 4 fuses) 
735632 
Crowbar Surge Protector 
715973