Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド

ページ / 132
Chapter 2    Installation and Configuration 
 
 
 
Upgrading an Existing Housing Lid 
The GainMaker Line Extender has a new style housing lid that allows easier access to the 
amplifier power supply. If you are replacing an earlier amplifier with a GainMaker 
amplifier, you will have to replace the existing housing lid with a newer housing lid to 
accommodate the power supply for the amplifier module. 
 
To Install the New Housing Lid 
Complete the following steps to upgrade an amplifier housing with the newest housing 
lid. 
 
CAUTION: 
RF connectors and housing seizure assemblies can be damaged if AC shunt 
power directors are not removed from the amplifier before installing or 
removing the amplifier module from the housing. 
 
 
WARNING: 
Before starting this procedure in an aerial or strand mounted application, be 
sure to clear the area below the housing of all people, and if possible, 
property. 
 
 
CAUTION: 
In an aerial or strand mounted application, you will need to take steps to 
ensure that the housing lid does not fall to the ground. See the following 
recommended procedure. 
Use a torque wrench to loosen the housing closure bolts on the housing lid. 
 
Firmly grasp the housing lid and open it carefully. 
Using a screwdriver, remove the hinge screw from the housing hinge. The housing 
lid will now swivel completely open, allowing it to be removed from the housing 
base. 
Important: Place the old housing lid in a safe place until it can be disposed of 
properly. 
 
18 
OL-31155-01