Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド

ページ / 132
Chapter 3    Balancing and Setup 
 
 
 
 
Switch S1 Position Information for AGC Stations 
 
Position 1 
Thermal Setup Mode 
Position 2 
Manual Setup Mode 
Position 3 
AGC Operational Mode 
A thermistor (thermal) driven 
circuit on the amplifier sets the 
DC control voltage that drives 
the Bode. 
This circuit detects the 
amplifier’s internal temperature 
and generates the proper level 
of DC control voltage, setting 
the proper loss characteristics of 
the Bode with respect to the 
current outdoor temperature. 
Note: This is the same as the 
“Thermal” toggle switch setting 
on most prior AGCs.   
The Manual Backoff 
potentiometer sets the DC control 
voltage that drives the Bode. 
Manually adjusting the Manual 
Backoff potentiometer sets the 
proper loss characteristics of the 
Bode with respect to the current 
outdoor temperature. 
Manual adjustment is done by 
monitoring the amplifier RF 
output level and adjusting the 
potentiometer to reduce the gain 
“x” dB from the full gain 
(minimum loss) of the 
potentiometer setting. 
The value of “x” (gain reduction) 
is dependant upon outside 
temperature and is determined by 
consulting the Manual Backoff 
Chart. 
Note: This is the same as the 
“Manual” toggle switch setting on 
some prior AGCs. 
The AGC detector circuit monitors 
the AGC pilot carrier level at the 
input to the AGC module. The 
detected AGC pilot carrier level 
variations cause a proportional 
variation of the DC control 
voltage that drives the Bode. 
Important: The switch must be 
left in this position after initial 
balancing in order for the AGC to 
function with the Bode properly. 
The AGC and Bode combination 
thus cause offsetting gain and 
slope variations to occur as 
needed, holding the actual 
amplifier output stable. 
Note: This is the same as the 
“Auto” toggle switch setting on 
all prior AGCs. 
Note: AGC operational mode is used only after the station has been initially balanced in 
either thermal or manual setup mode. 
 
Switch S1 Positions for Manual Stations 
The manual version of the GainMaker Line Extender does not have a Bode network 
installed. Therefore, switch S1 has no function in the manual version of the product. 
 
Switch S1 Positions for Thermal Stations 
The mode of thermal compensation you select for a thermal station determines the 
position in which you place switch S1. 
 
Position 1 - Selects amplifier only compensation mode 
 
Position 2 - Not used 
 
Position 3 - Selects amplifier and coax compensation mode 
Bode Network 
The Bode Network, or Bode, is an interstage variable attenuation and slope network 
whose loss characteristics are driven by DC control voltage. 
The position of switch S1 sets the DC control voltage driving the Bode according to the 
 
44 
OL-31155-01