Cisco Cisco 1 GHz GainMaker Amplifier データシート

ページ / 5
GainMaker
®
 - Unbalanced Triple - 5-40/52-1002 MHz 
 
3
 
 
Specifications 
 
General Station Performance 
Units 
Forward 
Reverse 
Notes 
Pass Band 
MHz 
52-1002 
5-40 
 
Amplifier Type 
--- 
GaAs FET 
PP 
 
Frequency Response 
dB 
±0.5 Main, ±0.6 Aux 
±0.4 
 
Auto Slope and Gain Range 
dB 
±5.5 
n/a  
Return Loss 
dB 
16 
16 
Max AC Through Current (continuous) 
Amps 
15 
 
Max AC Through Current (surge) 
Amps 
25 
 
Hum Modulation @ 12 A 
(over specified frequency range) 
dB 
70 (52-870 MHz) 
60 (870-1002 MHz) 
60 (5-10 MHz) 
70 (11-40 MHz) 
 
Hum Modulation @ 15 A 
(over specified frequency range) 
dB 
65 (52-870 MHz) 
60 (870-1002 MHz) 
60 (5-10 MHz) 
65 (11-40 MHz) 
 
Test Points (
± 0.5 dB) 
dB -20 
-20   
 
 
MAIN 
AUX 
 
 
Reference Output Level @…       1002 MHz 
870 MHz 
dBmV 
 
35 (@ 40 MHz) 
 
 
 
750 MHz 
 
 
 
650 MHz 
 
 
 
550 MHz 
 
 
 
55 MHz 
 
40.5 
38.5 
36.7 
35.0 
33.5 
26.0 
49.5 
47.5 
45.7 
44.0 
42.5 
35.0 
35 (@ 5 MHz) 
 
Reference Output Tilt  (55-1002 MHz) 
dB 
14.5 
 
 
Auto/Thermal  
with 10.5 dB I/S EQ 
Forward Station Performance 
Units 
 
 
MAIN
AUX 
Notes 
Operational Gain (minimum) 
dB 
34 
43 
Internal Tilt (
± 0.5 dB) 
dB +15.5 
+15.5 3 
Noise Figure @ 52 MHz 
dB 
8.5 
8.5 
Noise Figure @ 1 GHz 
dB 
7.5 
7.5 
78 NTSC Channels (CW) with digital 
 
 
 
Composite Triple Beat 
dB 
89 
79 
 
Cross Modulation 
dB 
79 
71 
Composite Second Order (high side) 
dB 
76 
73 
 
94 NTSC Channels (CW) with digital 
 
 
 
Composite Triple Beat 
dB 
84 
74 
 
Cross Modulation 
dB 
75 
67 
Composite Second Order (high side) 
dB 
74 
69 
 
 
Reverse Station Performance 
Units 
 
Notes 
Operational Gain (minimum) 
dB 
19.5 
6,7 
Internal Tilt (
± 0.5 dB) 
dB 0 3 
Noise Figure 
dB 
12 
6,7 
6 NTSC Channels (CW) 
 
 
 
Composite Triple Beat 
dB 
92 
 
Cross Modulation 
dB 
80 
Composite Second Order (high side) 
dB 
82 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Unless otherwise noted, specifications reflect typical performance and are referenced to 68
°F (20°C).  Specifications are based 