Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド
Upgrading Existing Housing Seizures
15
3 Using a ½ in. nut driver, install the new seizure screws from the upgrade in the
housing.
4 Do one of the following as appropriate:
If the coaxial cable is connected to the housing, tighten each seizure screw
from 2 ft-lb to 5 ft-lb (2.7 Nm to 6.8 Nm).
from 2 ft-lb to 5 ft-lb (2.7 Nm to 6.8 Nm).
If the coaxial cable is not connected to the housing, proceed to To Connect the
Coaxial Cable Pin Connector to the Amplifier Housing (on page 21).
Coaxial Cable Pin Connector to the Amplifier Housing (on page 21).
5 Place the blue stickers on the outside of the housing between the ports to indicate
that the upgrade has been completed.