Chapter 3    Balancing and Setup 
 
 
 
54 
 
 
5  Adjust the AGC gain control potentiometer to match the level you measured in 
step 3. 
 
6  Move switch S1 back and forth between position 2 and position 3. 
Important: Let the amplifier module settle before reading signal levels. 
The signal level should not vary when you switch between positions 2 and 3. If the 
signal level does vary, repeat steps 4 through 6 as needed until the signal level 
does not vary between switch positions 2 and 3. 
7  Set switch S1 to position 3 for AGC operation mode. 
8  Proceed to Balancing the Reverse Path (on page 68). 
 
Forward Path Balancing for AGC Stations Using Thermal Setup Mode 
Before you begin, make sure that you have configured the amplifier module 
according to the specifications in the design print, and that the amplifier has warmed 
up for approximately one hour.