Chapter 3        Balancing and Setup 
 
 
 
66 
 
 
6  Move switch S1 back and forth between position 1 and position 3. 
Important: Let the line extender module settle before reading signal levels. 
The signal level should not vary when you switch between positions 1 and 3. If 
the signal level does vary, repeat steps 4 through 6 as needed until the signal 
level does not vary between switch positions 1 and 3. 
7  Set switch S1 to position 3 for AGC operation mode. 
8  Proceed to Balancing the Reverse Path (on page 77). 
 
Forward Path Balancing for Thermal Stations Using Line Extender Only 
Compensation Mode 
Before you begin, make sure that you have configured the line extender module 
according to the specifications in the design print, and that the line extender has 
warmed up for approximately one hour. 
 
To Set Switch S1 for Line Extender Only Compensation Mode 
You must set switch S1 to position number 1 to use line extender only compensation 
mode.