Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド

ページ / 132
 
Chapter 3        Balancing and Setup 
 
 
 
72 
 
 
If the output tilt is more than design tilt, replace the forward input EQ with a 
lower value. 
 
If the output tilt is less than design tilt, replace the forward input EQ with a 
higher value. 
3  Measure the output tilt again, and then return to step 1. 
 
To Set the Output Level 
After setting the tilt, complete the following steps to select the proper pad values for 
the line extender. The output level of the line extender is set by selecting the proper 
pad value. 
Note: If you are setting the output level of a line extender that has not warmed up 
for approximately one hour, skip to the To Set the Output Level for a Cold 
Amplifier
 procedure below. 
To Set the Output Level for a Warm Line Extender 
1  Connect the test probe to the forward output test point. 
2  Measure the output level at the highest design frequency, and compare this level 
with the design level (on the design print). 
3  Is the measured output level within 
0.5 dB of the design level? 
 
If the output level is within 
0.5 dB of the design output level, proceed to 
Balancing the Reverse Path (on page 77). 
 
If the output level is more than the design output level, replace the forward 
input pad with a higher value pad. 
 
If the output level is less than the design output level, replace the forward 
input pad with a lower value pad. 
To Set the Output Level for a Cold Line Extender 
After setting the tilt, complete the following steps to select the proper pad values for 
the line extender. The output level of the line extender is set by selecting the proper 
pad value. 
Note: Using this procedure will result in a more accurate output level setting when 
balancing a line extender using line extender and coax compensation mode if the 
line extender has had little or no warm-up period. 
Important: For the most accurate output level setting, allow the line extender to 
warm up for approximately one hour and use the To Set the Output Level for a 
Warm Amplifier
 procedure above. 
1  Connect the test probe to the forward output test point.