Chapter 3        Balancing and Setup 
 
 
 
82 
 
reverse optical receiver RF output test point. 
a  Compare the received level to the reference level desired. 
b  If using a sweep system that is x dB below standard CW carrier levels, be 
sure to consider that the receive level should also be x dB below the CW 
reference level. 
c  To adjust the receive level to make it match the desired reference level, alter 
the value of the line extender reverse output pad. Each 1 dB increase in pad 
value should result in a corresponding 1 dB decrease in receive level, and 
each 1 dB decrease in pad value should give a 1 dB increase in receive level. 
3  Once the proper receive level and tilt of the test signals have been achieved, 
properly close the line extender housing and repeat the process at the next 
reverse amplifier in the downstream cascade. 
 
Important: 
 
Reinstall design print value reverse input pads for any port whose input pad 
may have been temporarily replaced with a 0 dB value pad for reverse path 
balancing purposes. 
 
Work outward from the node, and outward from each external split in the 
coaxial plant, until all line extenders in the cascade have been balanced. 
 
Repeat the process for all of the reverse amplifier cascades off any remaining 
active node ports until all reverse amplifiers feeding into the node have been 
balanced.