Cisco Cisco 1 GHz GainMaker Amplifier インストールガイド

ページ / 28
22 
GainMaker Amplifier Reverse Switch Removal Instruction Sheet 
748052 Rev C 
Line Extender Reverse Switch Removal,
 Continued 
 
3. 
Place the new 3”x 1” label over the existing label on the side of the chassis.   
 
 
4. 
Proceed to Repositioning the Amplifier Module in the Housing. 
Repositioning the Amplifier Module in the Housing 
Follow these steps to reposition the amplifier module in the housing. 
 
1. 
Line up the RF connectors on the amplifier module and the housing, then 
push the amplifier module into the housing. 
2. 
Using either a Phillips-head or T-15 Torx bit screwdriver, secure the cover to 
the amplifier module by tightening the 12 amplifier cover screws from 10 in-
lb to 12 in-lb (1.3 Nm to 1.4 Nm). 
Important:  The cover should lie completely flat on the amplifier chassis.  
Make sure none of the amplifier accessories prevent the cover from lying flat.