The table below lists the setup parameters of the OptoStar II 1550 nm optical 
amplifier module. 
Setup Parameters  Description 
Factory Default 
Laser Status 
ON/OFF 
Shows/sets laser status: ON/OFF  Laser Status: OFF 
Optical input 
power alarm 
threshold   
Shows/sets optical alarm upper 
limit and lower limit 
Lower limit: - 5.0 dBm 
Upper limit: + 10.0 
dBm 
Optical output 
power alarm 
threshold   
Shows/sets optical alarm upper 
limit and lower limit 
Lower limit: standard 
value - 4.0 dBm; 
Upper limit: standard 
value + 1.0 dBm 
Alarm ON/OFF 
Shows/sets module alarm status: 
ON/OFF 
Alarm status: ON 
Restart setting 
Sets up restart of the optical 
amplifier 
-- 
Factory Setting   
Restores the factory settings of 
the optical amplifier 
-- 
 
 
 
 
 