Setup Parameters
The table below lists the alarm parameter settings of the OptoStar II 1550 nm
optical amplifier module.
optical amplifier module.
Setup Parameters
Description
Factory Default
Laser Status
ON/OFF
Shows / sets laser status:
ON/OFF
Laser Status: OFF
Input optical
power alarm
threshold
Shows/sets optical alarm upper
limit and lower limit
Lower limit: - 5.0 dBm
Upper limit: + 10.0
Upper limit: + 10.0
dBm
Output optical
power alarm
threshold
Shows/sets optical alarm upper
limit and lower limit
Lower limit: standard
value - 4. 0 dBm;
Upper limit: standard
value +1. 0 dBm
Alarm ON/OFF
Shows/sets module alarm status:
ON/OFF
Alarm status: ON
Restart setting
Sets up restart of the optical
amplifier module
--
Factory Setting
Restores the factory settings of
the optical amplifier module
--
Continued on next page
OL-29664-05