Starting up the Module 
Initialization 
When the OptoStar II optical switch module is powered on, the module will 
perform a self-test. 
Follow these steps to perform the self-test: 
1.  Turn the front panel switch of the OptoStar II power supply module to ON 
position. 
2.  When the optical switch module starts up, it will perform a booting 
initialization for about 5 seconds. 
3.  During the initialization, the power LED and the alarm LED on the front 
panel will be illuminated, and the communication status is shut off. 
4.  Once the initialization is completed, the status indicator will return to normal. 
Communication is enabled and the module is operational. 
CAUTION: 
• 
The module must be initialized; any equipment that cannot be initialized must 
be returned to the manufacturer for repair. 
• 
When everything becomes stable, the module still needs to warm up for at least 
one hour, to make sure that its performance is normal. 
Signal Inspection 
Check whether the A/B optical input power is between -15dBm and +25dBm 
with an optical power meter. Also use a power meter to check whether the 
optical output power is within the specifications. 
 
 
 
 
 