Cisco Cisco OptoStar II Driver Amplifier インストールガイド

ページ / 64
Operating using ICIM LCD, Continued 
Alarm Code List 
The table below lists the alarm information of the OptoStar II RF switch module. 
Code 
Item 
Condition 
LED 
001 
Low RF Input Level 
in Channel A 
Channel A input level < 
calibrated signal level - 
preset threshold 
Alarm LED is red 
002 
High RF Input Level 
in Channel A 
Channel A input level > 
calibrated signal level + 
preset threshold 
Alarm LED is red 
003 
Low RF Input Level 
in Channel B 
Channel B input level < 
calibrated signal level - 
preset threshold 
Alarm LED is red 
004 
High RF Input Level 
in Channel B 
Channel B input level > 
calibrated signal level + 
preset threshold 
Alarm LED is red 
011 
High Module 
Temperature 
Module temperature 
higher than 85°C 
Alarm LED is red 
 
 
 
 
 
OL-29669-02 
Operation 
3-13