Cisco Cisco OptoStar II Driver Amplifier インストールガイド

ページ / 71
Operating using ICIM LCD, Continued 
Alarm Code List 
The table below lists the alarm information of the OptoStar II reverse receiver 
module. 
Code 
Item 
Condition 
LED 
001 
Module 1 Low Optical 
Input Power 
Optical input power 
lower than -17 dBm 
Alarm LED is red 
002 
Module 1 High Optical 
Input Power 
Optical input power 
higher than 3 dBm 
Alarm LED is red 
003 
Module 2 Low Optical 
Input Power 
Optical input power 
lower than -17 dBm 
Alarm LED is red 
004 
Module 2 High Optical 
Input Power 
Optical input power 
higher than 3 dBm 
Alarm LED is red 
005 
Module 3 Low Optical 
Input Power 
Optical input power 
lower than -17 dBm 
Alarm LED is red 
006 
Module 3 High Optical 
Input Power 
Optical input power 
higher than 3 dBm 
Alarm LED is red 
007 
Module 4 Low Optical 
Input Power 
Optical input power 
lower than -17 dBm 
Alarm LED is red 
008 
Module 4 High Optical 
Input Power 
Optical input power 
higher than 3 dBm 
Alarm LED is red 
009 
High Module 
Temperature 
Module temperature 
higher than 85°C 
Alarm LED is red 
 
 
 
 
 
3-16 
 
Operation 
OL-29663-03