Unified ICM Configuration 
 
44 
application to indicate the event. The DMS100 PG uses the DV-Appl-Stat-
QryF
1
F interface to periodically interrogate the DMS100 switch for the all 
monitored ACD groups to examine whether the Agents have been re-
assigned from one Skill Group to another Skill Group. 
The DV-Appl-Stat-Qry interface is supported in the CompuCALL 
software version NA09 or above. 
Because of periodical interrogation, the DMS100 PG will not know any 
Agent Skill Group re-assignment until the next time it interrogates the 
ACP1000 switch. The interval is controlled by the Windows NT Registry 
entry, “..\DMS100Data\ Dynamic\AgentGroupChangeTimerResolution”. 
The default value for “..\DMS100Data\ 
Dynamic\AgentGroupChangeTimerResolution” is 0 that virtually disables 
the DMS100 PG option to periodically interrogate the DMS100 switch. 
There is CompuCALL link bandwidth consideration when applying the 
approach to deal with the Agent Skill Group re-assignment. When the 
DMS100 PG used the DV-Appl-Stat-Qry interface, the DMS100 will 
acknowledge with a DV-Agent-Status-U message for each Agent. The 
DMS100 switch CompuCALL X.25 link with 19.2 kbps can deliver 
messages for 5 calls/second, assuming 4 messages per call statistically. If 
the DMS100 PG interrogates the switch with 240 ACD agents configured 
for Agent Skill Group re-assignment every minute, the DMS100 switch 
can only deliver the CompuCALL message for 4 calls/second. This is 
because there are extra 240 DV-Agent-Status-U messages in every minute. 
 
                                                      
1
 When a new DN is added in the PMT of the PG explorer, the PIM sends a 
request to associate with the DMS100 switch. If the DN is successfully 
associated with the DMS100 switch for the first time, PIM sends the “DV-Appl-
Stat-Qry” message to the DMS100 switch. If the switch responds with the error 
“ACD DN missing,” the PIM tries to associate the DN 8504889080 for a 
second time. As a result, the DMS100 switch responds with an error “DN 
Already In Set.” Due to this, the DMS100 PIM cycles. This issue is caused due 
to the incorrect error message sent by the Nortel DMS100 switch.