Cisco Cisco IP Contact Center Release 4.6.1 テクニカルリファレンス

ページ / 62
 
 
 DMS-100 CompuCALL Interface Specification (Q218) 
47 
 
 
47 
47 
 
TotalBytesPC  -  total bytes per call (byte/call), 
 
ByteToBit 
- bits in one byte (= 8), 
 
Occu 
 
- planed CompuCALL message occupancy of 
X.25 link (e.g. 60%). 
 
Formula 2:   
BandWidth (bit/sec)  = CallsPS * TotalBytesPC  *  ByteToBit * Occu 
Where:  CallsPS  -  average calls per second (call/sec). 
Table 18: DMS-100 Switch Capacity 
Parameter 
Maximum 
Value 
Meaning 
SN
max
 
96 
Maximum active CompuCALL sessions 
per switch 
SVC
max
 
Maximum SVCs per CompuCALL 
session 
ACDDN
max
 
20 
Maximum ACD Groups associated to 
one CompuCALL session 
DN
max
 
20000 
Maximum non-ACD DNs associated to 
one CompuCALL session 
LinkBD 
19.2 (kbps) 
CompuCALL link bandwidth (kbits/sec) 
AcSVC
max
 
96 
Maximum active SVCs per DMS-100 
switch 
Cus
max
 
81 
Maximum customer number per DMS-
100 switch 
Note:  Nortel recommends only one SVC per CompuCALL link. 
 
Table 19: DMS-100 Switch Statistics Provided by Nortel 
Parameter 
Maximum 
Value 
Meaning 
CSL
sta
 
5  
Statistically estimated maximum calls per 
second on one active CompuCALL link 
(Calls/Sec/Link). 
MSL
sta
 
20 
Statistically estimated maximum 
messages per second on one active 
CompuCALL link (Messages/Sec/Link). 
BM
sta
 
90 
Statistically estimated average bytes per 
CompuCALL messages (Bytes/Message).