Cisco Prisma FiberLinX Modules (CWDM) データシート

ページ / 5
1310 / 1550 nm FiberLinX Modules 
 
2
 
 
Application 
 
When used in pairs, a Prisma FiberLinX module configured as a Host resides at the headend while another Prisma 
FiberLinX module configured as a Remote, is installed at the remote customer location, typically on the network 
edge where the customer network meets the service provider infrastructure.  Via SNMP, the Prisma FiberLinX 
solution monitors the entire link and ensures data integrity while remaining isolated and completely transparent to 
the customer LAN.  A Prisma FiberLinX module can be configured as a Standalone for a single-solution (CPE) 
application. 
 
 
2-Fiber Block Diagram 
Headend/Hub
Customer Premise
Remote FiberLinX
Host FiberLinX
100BASE FX
Single or Multi Mode Fiber
SNMP
Management
only
Data only
or
Data and SNMP
Management
10/100BASE TX
Data
(LAN)
10/100BASE TX
10/100BASE TX
RX
TX
RX
TX
 
 
 
Single-Strand Fiber Block Diagram 
Headend/Hub
Customer Premise
Remote FiberLinX
Host FiberLinX
100BASE FX
Single-Strand Fiber
SNMP
Management
only
Data only
or
Data and SNMP
Management
10/100BASE TX
Data
(LAN)
10/100BASE TX
10/100BASE TX
RX
TX
RX
TX
1310 nm
1550 nm
1310 nm
1550 nm