General Troubleshooting Information, Continued 
 
Alarm 
Possible Cause 
Servicing Instruction 
No RF output   
 
The forward optical 
transmitter module 
has no optical output 
power 
 
Link optical 
distributor failure 
 
If the optical input 
power and output 
signal at the test point 
meet specifications, 
and RF output port 
has no signal, it 
indicates failure of the 
F connector at the RF 
output port.   
 
If the optical input 
power meets 
specifications, and the 
test point and RF 
output port have no 
signal, it indicates 
failure of the amplifier 
module inside the 
forward receiver 
module.   
 
Inspect the optical 
output power of the 
forward optical 
transmitter module to 
make it within the 
correct range 
 
Check if link optical 
distributor has optical 
signals 
 
Check if RF connector 
matches and 
troubleshoot conenctor 
failure   
 
Measure if the optical 
input power meets the 
specifications.   
 
Measure if the output 
signal at the test point 
meets specifications 
 
Measure if the signal 
strength at the RF output 
port meets specifications 
 
Contact the 
manufacturer for 
servicing when there is 
still no RF output 
High Module 
Temperature 
 
High ambient 
temperature leading 
to insufficient heat 
dissipation 
 
Poor chassis 
ventilation 
 
Chassis fan failure 
 
Make sure the ambient 
temperature is within 
the working temperature 
range of the module.   
 
Ensure good chassis 
ventilation 
 
In case of fan failure, 
replace the fan, or 
contact the manufacturer 
for servicing 
 
CAUTION: 
Do not open the enclosure of this module in any case. Opening the enclosure 
may result in equipment damage, and you may lose the warranty eligibility. 
 
 
4-6 
Troubleshooting 
OL-29662-03