Note: SAN connectivity is configured for the ESXi host iSCSI software adapter: 
•  The iSCSI port (TCP port 3260) must be enabled in the VMware firewall.
•  The iSCSI software initiator must be enabled on ESXi hosts.
•  Secure Shell (SSH) must be enabled on the ESXi hosts to allow VSAs to be deployed.
SvSAN uses the network ports shown in Table 5.
Table 5.  Network Ports 
Component or Service
Protocol or Port
Discovery
UDP 4174
XMLRPC server
TCP 8000
Inter-VSA communications
TCP 4174
SMD XML RPC
TCP 43127
Web Access
TCP 80 and 443
Management services
TCP 8990
vSphere Client plug-in
TCP 80 and 443
Miscellaneous VMware services
TCP 16961, 16962, and 16963
For additional port numbers used by SvSAN, see the following URL: 
.
Configure ESXi Host Networking
1.  Create virtual standard switches in all the ESXi hosts as described here:
•  vSwitch0
 
- VMkernel Port: Management network
 
- Virtual Machine Port Group: Production virtual machines and SvSAN management 
•  vSwitch1
 
- VMkernel Port: iSCSI traffic
 
- Virtual Machine Port Group: SvSAN iSCSI and mirror traffic
•  vSwitch2
 
- VMkernel Port: iSCSI traffic
 
- Virtual Machine Port Group: SvSAN iSCSI and mirror traffic
•  vSwitch3
 
- VMkernel Port: vMotion
2.  Edit all the vSwitches and VMkernel ports used for iSCSI, mirror, and vMotion traffic and set the MTU size to 9000, as 
shown in Figures 42 and 43.