Cisco Cisco SG200-26P 26-port Gigabit PoE Smart Switch

ページ / 22
Release Notes for 200, 300, 500, and ESW2 Series Switches Firmware Version 1.3.5.x
13
Release Notes
Problem:
When the Chinese localization file is installed on the SX500 stack 
master from TFTP on the web GUI, and the stack cable between master and 
backup unit is removed, the localization file is not installed on the backup unit. If CLI 
is used, or if the file is copied through http, this issue is not observed. (CQ150000, 
CSCuj46533)
Solution:
Use HTTP to install localization file.
Problem:
When the firmware is upgraded from 1.3.0 to 1.3.5, both firmware 
images (active and non active) are saved as 1.3.5 in the flash memory. (CQ148800, 
CSCuj46557)
Solution:
There is no workaround.
Problem:
Sometimes LAG port cannot be up when using 1G SFP. This happens 
on SG500XG-8F8T and 10G SFP port. (CQ150142, CSCuj37498)
Solution:
Keep the link up and reload the device.
Problem:
Using the web GUI to edit the default port in the Neighbor Discovery 
Inspection Policy table takes more than 10 seconds. (CQ150135, CSCuj37395)
Solution:
Configure using CLI.
Problem:
When Maximal Router Preference set to No Verification on the web GUI, 
Minimal Router Preference cannot be configured. It displays a message stating 
“Maximal router preference verification level must be higher than or equal to the 
minimal router preference verification level”. This issue is noticed only on the Web 
GUI. (CQ150108, CSCuj46567)
Solution:
Configure using CLI.
Problem:
When multiple resolved host names exist in web GUI, usually the last 
one or two entries cannot be deleted. (CQ149930, CSCuj46576)
Solution:
Delete any of the above entries first, then delete last one or two entries.
Problem:
When multiple different class PDs are connected to SF300-48PP, 
sometimes two or three ports are not delivered power although there is still power 
budget. This happens when Consumed Power is about 324 watt (86%) or more. 
(CQ147622, CSCuj46584)
Solution:
There is no workaround.
Problem:
The Stack Port LED on the System Summary page of the web GUI is 
inconsistent with front panel of SG500XG-8F8T. (CQ150109, CSCuj46594)
Solution:
There is no workaround.