Brother HL-1850 ユーザーガイド

ページ / 149
CHAPTER 13 TROUBLESHOOTING 
13-13
 
Novell NetWare Troubleshooting 
 
If you cannot print from NetWare and you have checked the hardware and 
network as described in the previous steps, first verify that the Brother print 
server is attached to the server queue by going to PCONSOLE, selecting PRINT 
QUEUE INFORMATION, and then CURRENTLY ATTACHED SERVERS. If 
the print server does not appear in the list of attached servers, then check the 
following: 
 
It is always a good idea to try followings in order to eliminate the possibility of 
setup errors 
• 
Turning off the printer and then on again to force to rescan the Netware 
queue. 
• 
Deleting and recreating the print server and creating a new print queue in 
order to eliminate the possibility of setup errors. 
 
 
1.  If you changed the login password, you must change the password in 
both the Brother print server (using the SET NETWARE PASSWORD 
command if you are using the BRConfig software) or by using a web 
browser or the BRAdmin application and in the file server (using the 
PCONSOLE Print Server Information Change Password command). 
 
2.  If you created the print queue using PCONSOLE and instead of 
BRAdmin, make sure that you have enabled at least one NetWare file 
server using the SET NETWARE SERVER servername ENABLED 
command. 
 
3.  Have you exceeded your NetWare user limit? 
 
4.  Make sure that the print server name you used in PCONSOLE exactly 
matches the name that is configured in the print server, and make sure it 
is defined as a Queue Server for the print queue. 
 
5.  If you are running both 802.3 and Ethernet II frames on different file 
servers on your network, there is a possibility that the print server may 
not make a connection to the desired file server. Try forcing the frame 
type to the desired one using the SET NETWARE FRAME command 
from the print server remote console or using BRAdmin. 
 
6.  If you are using DOS CAPTURE statement and losing portions of your 
print job, try setting the TIMEOUT parameter in your CAPTURE 
statement to a higher value (at least 50 seconds for Windows).