Brother RJ-2140 参照ガイド
Raster Command Reference
- 28 -
7. Printing Command Details
7. Printing Command Details
NULL
Invalidate
ASCII:
NULL
Hexadecimal: 00
Description
Skipped
The specified number of bytes depending on the model will be sent.
(RJ-3000: 350 bytes, RJ-2000: 200 bytes)
ESC @
Initialize
ASCII:
ESC
@
Hexadecimal: 1B
40
Description
Initializes mode settings.
Also used to cancel printing.
ESC i S
Status information request
ASCII:
ESC
i
S
Hexadecimal: 1B
69
53
Description
Send a request to the printer for status information. For details on the status, refer to the previous section.
The size is fixed at 32 bytes.
Note
Before sending print data to the printer, this command should be sent once. Since error
information is automatically sent by the printer during printing, do not send this command while
printing.