Brother RJ-3050 参照ガイド
![Brother](https://files.manualsbrain.com/attachments/8c662d2d9dbf4f824dfb46b9a1ababe38c435c2d/common/fit/150/50/d9563199756797e8650c01d5929471667ad930bd23805d8d5e013c9eee84/brand_logo.png)
P-touch Template 2.0 Command Reference
- 36 -
7. Control Command Details
^PC
Specify print start received character count
ASCII:
^
P
C
n1
n2
n3
Decimal:
94 80 67 nd1 nd2
nd3
Hexadecimal: 5E 50 43 nh1 nh2
nh3
Parameters
0≤n1≤9
0≤n2≤9
0≤n3≤9
Description
Specifies the number of characters to be received in order to start printing.
(n1*100)+(n2*10)+n3: Print start received character count (bytes) (1 to 999)
The default print start received character count is 10.
This command is a dynamic command.
Example
To change the print start received character count to 100 characters:
Since n1=1, n2=0 and n3=0, the command will be as follows.
^ P C 1 0 0