Intel SR1695GPRX1AC ユーザーズマニュアル
Power Sub-System
Intel® Server System SR1695GPRX TPS
Revision
1.5
Intel order number: G11332-006
16
The power supply output voltages shall remain within limits specified in below table for the step
loading and capacitive loading specified in Table 4 below. The load transient repetition rate
shall be tested between 50 Hz and 5 kHz. The load transient repetition rate is only a test
specification. Each rail’s remote sense is connected to the respective output cable termination
at the mating connector(s).
loading and capacitive loading specified in Table 4 below. The load transient repetition rate
shall be tested between 50 Hz and 5 kHz. The load transient repetition rate is only a test
specification. Each rail’s remote sense is connected to the respective output cable termination
at the mating connector(s).
Table 12. Dynamic Tolerance Requirement
Output
Min
Nom
Max
Tolerance
+3.3V
3.135 V
+3.300V
3.465 V
+/-5%
+5V
4.750 V
+5.000V
5.250 V
+/-5%
+5VSB
4.750 V
+5.000V
5.250 V
+/-5%
+12V
11.400 V
+12.000V
12.600 V
+/-5%
3.2
AC Voltage Input Specification
3.2.1
Input Voltage And Frequency
The power supply must operate within all specified limits over the following input voltage range.
Harmonic distortion of up to 10% THD must not cause the power supply to go out of specific
limits. The power supply shall be capable of start-up (power-on) with full rated power load, at
line voltage as low as 90VAC.
Harmonic distortion of up to 10% THD must not cause the power supply to go out of specific
limits. The power supply shall be capable of start-up (power-on) with full rated power load, at
line voltage as low as 90VAC.
Table 13. AC input rating.
Parameter
Min
Rated
Max
Start up VAC
Power Off VAC
Max Input Current at
Min Vrms
120VAC 90
V
rms
100-127
V
rms
132
V
rms
< 85 V
ac
<
80V
ac
6
A
rms
220VAC 180
V
rms
200-240
V
rms
264
V
rms
3
A
rms
Frequency
47 Hz
63 Hz
3.2.2
AC input Power Factor
The typical power factor shall be greater than 0.98 at 90Vac/47Hz with loading
specified below.
Table 14. Typical power factor for 110VAC
90Vac/47Hz
5VSB
12V Main
Output Watts
Min PF
100% load
2.8 A
32.2A
400.4W
0.98
The typical power factor shall be greater than 0.94 at 90Vac/60Hz with loading
specified below.
Table 15. Typical power factor for 110VAC
240Vac/60Hz
5VSB
12V Main
Output Watts
Min PF
100% load
2.8A
32.2A
400.4W
0.95