Cooling Sub-System 
Intel® Server System SR1695GPRX TPS 
  
Revision 
1.5 
Intel order number: G11332-006 
32
 
Figure 17. Air Duct Position in System 
 
4.5 
Drive Bay Population Requirement 
In order to maintain system thermal requirements, you must fully populate all hard drive bays. 
Hard drive trays used for hot-swap drives must either have a hard drive installed or not have a 
hard drive installed. 
IMPORTANT: If the drive bay is missing or not fully populated, the system will not meet the 
thermal cooling requirements of the processor, which will most likely result in degraded 
performance as a result of throttling or thermal shutdown of the system. It is recommended to 
apply the air block on the blank HDD carrier if the installed HDD quantity is less than 
four pieces.