Intel SR1695GPRX1AC ユーザーズマニュアル
Intel® Server System SR1695GPRX TPS
Environmental and Regulatory Specifications
Revision 1.5
57
Intel order number: G11332-006
Over-current protection: The server is designed for an AC line voltage source with up to 20
amperes of overcurrent protection per cord feed. If the power system for the equipment rack is
installed on a branch circuit with more than 20 amperes of protection, you must provide
supplemental protection for the server.
amperes of overcurrent protection per cord feed. If the power system for the equipment rack is
installed on a branch circuit with more than 20 amperes of protection, you must provide
supplemental protection for the server.
10.8
Power Cord Usage Guidelines
Warning: Do not attempt to modify or use a power cord set that is not the exact type required.
You must use a power cord set that meets the following criteria:
You must use a power cord set that meets the following criteria:
Rating: In the U.S. and Canada, cords must be UL (Underwriters Laboratories, Inc.) Listed/CSA
(Canadian Standards Organization) Certified type SJT, 18-3 AWG (American Wire Gauge).
Outside of the U.S. and Canada, cords must be flexible harmonized (<HAR>) or VDE (Verband
Deutscher Electrotechniker, German Institute of Electrical Engineers) certified cord with 3 x 0.75
mm conductors rated 250 VAC (Volts Alternating Current).
Outside of the U.S. and Canada, cords must be flexible harmonized (<HAR>) or VDE (Verband
Deutscher Electrotechniker, German Institute of Electrical Engineers) certified cord with 3 x 0.75
mm conductors rated 250 VAC (Volts Alternating Current).
Connector, wall outlet end: Cords must be terminated in grounding-type male plug designed for
use in your region. The connector must have certification marks showing certification by an
agency acceptable in your region and for U.S. must be Listed and rated 125% of overall current
rating of the server.
agency acceptable in your region and for U.S. must be Listed and rated 125% of overall current
rating of the server.
Connector, server end: The connectors that plug into the AC receptacle on the server must be an
approved IEC (International Electrotechnical Commission) 320, sheet C13, type female
connector.
connector.
Cord length and flexibility: Cords must be less than 4.5 meters (14.76 feet) long.
10.9
Product Ecology Compliance
Intel
®
has a system in place to restrict the use of banned substances in accordance with
worldwide product ecology regulatory requirements. The following is Intel’s product ecology
compliance criteria.
compliance criteria.
Compliance Regional
Description
Compliance Reference
Compliance Reference Marking
Example
California
CA. Lithium Perchlorate insert
California Code of Regulations, Title 22, Division 4.5;
Chapter 33: Best Management Practices for Perchlorate
Materials.
California Code of Regulations, Title 22, Division 4.5;
Chapter 33: Best Management Practices for Perchlorate
Materials.
Special handling may apply.
See
See
www.dtsc.ca.gov/hazardous
waste/perchlorate
waste/perchlorate
This notice is required by
California Code of
Regulations, Title 22,
Division 4.5; Chapter 33:
Best Management Practices
for Perchlorate Materials.
This product/part includes a
battery which contains
Perchlorate material.