Appendix A: Integration and Usage Tips 
Intel® Server System SR1695GPRXTPS 
  
Revision 
1.5 
Intel order number: G11332-006 
60
Appendix A: Integration and Usage Tips 
Before attempting to integrate and configure your system, you should reference this section, 
which provides a list of useful information. 
ƒ
  After the system is integrated with processors, memory, and peripheral devices, the 
FRUSDR utility must be run to load the proper Sensor Data Record data to the 
integrated Server Management subsystem. Failure to run this utility may prevent Server 
Management from accurately monitoring system health and may affect system 
performance. The FRUSDR utility for this server system can either be run from the Intel
®
 
Deployment CDROM that came with your system, or can be downloaded from the Intel
®
 
website referenced at the bottom of this page.  
ƒ
  To ensure the highest system reliability, make sure the latest system software is loaded 
on the server before deploying the system onto a live networking environment. This 
includes system BIOS, FRUSDR, BMC firmware, and hot-swap controller firmware. The 
system software can be updated using the Intel
®
 Deployment CDROM that came with 
your system or can be downloaded from the Intel
®
 website referenced at the bottom of 
this page. 
ƒ
  System fans are not hot-swappable. 
ƒ
  Only supported memory validated by Intel
®
 should be used in this server system. A list of 
supported memory can be found in the Intel
®
 Server System SR1695GPRX Tested 
Memory List which can be downloaded from the Intel
®
 website referenced at the bottom 
of this page. 
ƒ
  This system supports the Intel
®
 Xeon
®
 processor 3400 and Core™ i3 sequence. You 
cannot use Intel
®
 Xeon
®
 processors not referenced on the supported processor list in 
this server system. 
ƒ
  You must use the CPU/memory air duct to maintain system thermals. 
ƒ
  To maintain system thermals, you must populate all hard drive bays with either a hard 
drive or drive blank. 
ƒ
  You must remove AC power from the system prior to opening the chassis for service 
You can download the latest system documentation, drivers, and system software from the 
Intel
®
 Support website at 
http://www.intel.com/p/en_US/support/highlights/server/s3420gp.