14
6.  The requirements for RS485 control is as follows :
Signaling Speed: 9600 bps
Data Bit : 8 bits
Stop Bit : 1 bit
Parity Bit : none
PROTOCOL   
SAMSUNG
ADDRESS     
0
TYPE            
RS-485, HALF 
BAUD RATE    9600
LENS            
OK
EEP VER       
1.0 
ROM VER      
1.0
4.  Determine the type of power supply and set the POWER
SELECTION switch accordingly. Next, plug the power
adapter into a wall outlet. 
The requirements for the power adapter for each model are
as follows:
SCC-C4205(P)  : DC12V 600mA
SCC-C4305(P) : AC24V 300mA
DC12V 600mA
5.  If the camera operates normally, the following screen will
be displayed for 5 seconds and then disappears.
13
1. Connect one end of the BNC cable to the VIDEO OUT.
2. Connect the other end of the BNC cable to the VIDEO IN
of the monitor.
3.  Plug in the power adapter. Use a "minus" screwdriver to
connect one part of the power adapter, which consists of 
two lines, to the POWER terminal of the camera as follows :
REMOTE
RS-485
PWR IN
REMOTE
RS-485
POWER
Video terminals on the back
of the monitor
BNC cable
POWER SELECTION switch
underneath the power adapte
POWER SELECTION
switch underneath the
power adapte
Connecting the Cables